Page in Acrobat Reader format (359kB) |
CONVERTERS OF Pt100 RESISTANCE,
TRANSMITTER RESISTANCE AND THERMOELECTRIC VOLTAGE
PPN24, PPN230 |
Pt100 RESISTANCE, TRANSMITTER RESISTANCE AND THERMOELECTRIC VOLTAGE
CONVERTER WITH AUXILIARY POWER SUPPLY |
Profile: |
| PPN24, PPN230 |
 |
Description: |
- designed for DIN rail mounting
- the auxiliary power supply is isolated from other circuits
- conversion accuracy < 0,3%
- low cost |
The module has been designed to convert the output
of a resistance thermometer, resistance transmitter or thermocouple into a unified output series
(0..10V, 0..20mA, 4..20mA). The resistance sensors may be either two-wire or three-wire connected. The
module can handle output voltages of any standard Platinum or Nickel sensors, carrying out their
temperature-to-resistance transfer function linearization at a time. Two options of the resistance
transmitter circuit connection are available, namely, variable resistance and potentiometer. The
converter can also handle any standard thermocouple voltages. It provides the thermocouple cold
junction compensation at the place of the converter's input terminals. However, no linearization of the
thermocouple voltage vs. temperature response curve is provided. The converter input and output circuits
are not isolated from each other. |
Electrical specifications: |
| - operating temperature range: |
-25...+70°C |
| - supply voltage: |
24V DC ± 30% for PPN24 |
| |
230V AC ± 10% ( 45 - 65 Hz ) for PPN230 |
| - power input: |
max. 2VA |
| - current limit: |
30mA±5mA |
| - maximum output voltage: |
27V |
| - output voltage amplitude: |
min. 15V (R load-750W) at 20mA |
| - voltage output load: |
max. 10mA |
| - inputs: |
Pt100, 1000 to IEC 751, any range from -50 to +600°C |
| |
(TMAX-TMIN) = cca 50...600°C |
| |
Ni100, 500, 1000 preferably for TKR 6180 ppm/K |
| |
variable resistance ranging 50W .. 800W in three-wire (3w) connection |
| |
variable resistance ranging 1KW .. 10KW 2w connection (terminal 2 not connected) |
| |
potentiometer ranging 50W .. 10kW |
| |
thermocouple E, J, K, T, R, S, B, T without linearization |
| |
arbitrary range (TMAX-TMIN) = cca 50...1600°C |
| - input connection: |
two or three-wire / two-wire for a thermocouple |
| - Pt100 lead-in wire resistance compensation: |
< 0,03%/1W |
| - cold junction temperature compensation: |
by means of a Pt100 internal sensor fitted at the converter terminals < ±1°C |
| - linearization method: |
parabolic curve for Pt and Ni, otherwise no linearization |
| - output: |
0..1V, 0..5V, 0..10V, 0..5mA, 0..20mA, 4-20mA |
| - accuracy: |
measurement error: |
< 0,3% |
| |
linearity error: |
< 0,1% |
| |
temperature induced error: |
< 0,02%/°C |
| - enclosure: |
casing / terminal board: |
IP40 / IP10 |
| - dielectric strength: |
4000Vr.m.s., 50Hz/1 min |
| - settling time: |
300ms |
| |
|
|
| Type tests: |
Standard type test:
EMC:
Safety: |
to CSN EN 60770-1
to CSN EN 61326-1
assessed acc. to CSN EN 61010-1 |
Terminal connection: |
1, 2, 3 ...........
4,5.................
6,7................. |
see application examples
output (5 is +)
24V DC power supply terminals (7 is +), or 230V AC depending on the type |
| The terminals accept wires with cross sections not exceeding 2,5mm2. |
| |
 |
Converter dimensions:
|
| |
 |
Ordering instructions:
The device has a fixed factory setting. The input signal
type and range cannot be changed. The output setting is fixed, too. This information must therefore
be included in your purchase order.
Your purchase order should include: converter type, input
signal type and range, output signal type and range, number of pieces. Special requirements must be
discussed with us beforehand.
Most frequently ordered input ranges:
|
| RTD |
Pt100 -50...+50°C
Pt100 -50...+100°C
Pt00 -20...+60°C
Pt100 0...+50°C
Pt100 0...+100°C
Pt100 0...+200°C
Pt100 0...+250°C
Pt100 0...+300°C
Pt100 0...+400°C
Pt1000 0…+100°C
Pt1000 0…+200°C
Ni1000 0…+100°C
Ni1000 0…+200°C |
OV |
3w 0...100W
3w 5...105W
2w 0...500W
2w 0...1000W
2w 0...10000W
2w 0...10KW |
Tc |
"J" 0…+200°C
"J" 0...+400°C
"J" 0...+600°C
"J" 0...+800°C
"K" 0...+100°C
"K" 0...+400°C
"K" 0...+600°C
"K" 0...+900°C
"K" 0...+1000°C
"K" 0...+1200°C
"S" 0...+1400°C
"S" 0...+1600°C
... other ranges by request |
| Potentiometer |
Pot. 0...100W
Pot. 5...105W
Pot. 0...105W
Pot. 0...1KW
Pot. 0...10KW |
| |
| Examples: |
PPN24 Pt100 0...+100°C/4..20mA, 1 pc.
PPN24 potentiometer 0...1000W/0..20mA, 2 pcs.
PPN230 OV 5...105W/0..10V, 3 pcs.
PPN230 Tc "K" 0...+1000°C/0..10V, 3 pcs. |
|
|