Products
- digital processing of the input signal
- measurement frequency of AC grid
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- converter with galvanic isolation 4000Veff input - output - power supply
- it is designed for transduction:
- temperature from any thermocouple with linearization and cold junction compensation
- temperature from RTD, thermistors, KTY or NTC sensors
- resistance from resistance transmitter (potentiometer) 0..320Ω, 0..2500Ω
- sw programmable active output 4-20mA, 0-20mA or 0-10V, eventually inverted
- power supply in wide range 19..300VDC amd 90..250VAC
- easy programming by AX-USB adapter (AY-USB)
- DIN 35 rail-mounted design
- two-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- bidirectional transmission of FSK signal HART communication
- transfer 1:1 via transformer
- input voltage drop 2,7V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 1,5kV
- measurements outputs from Pt100 resistance thermometers or J,K thermocouples
- 4-digit red LED display ( height 20mm)
- universal power supply
- panel design IP65
- one measuring system
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- converter with galvanic isolation 4000Veff input - output - power supply
- it is designed for transduction:
- resistance from resistance transmitter (potentiometer) 0..150Ω, 0..1300Ω a 0..11kΩ e.t.c.
- linear KTY sensors
- sw programmable active output 4-20mA, 0-20mA or 0-10V, eventually inverted
- power supply in wide range 19..300VDC amd 90..250VAC
- easy programming by AX-USB adapter (AY-USB)
- DIN 35 rail-mounted design
- measurements
- AC current or voltage
- DC current or voltage
- frequency
- 4-digit red LED display ( height 20mm)
- universal power supply
- panel design IP65
- one-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- transfer 1:1 via transformer
- input voltage drop 2,8V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 4kV
- one measuring system - alternative connection with virtual neutral wire
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- převodník s galvanickým oddělením 4000Vef vstup – výstup – napájení
- převádí signál:
- z potenciometru 0..100Ω až 15kΩ
- v uvedeném rozsahu nezávisí na hodnotě potenciometru ( např. potenciometr 5kΩ v rozsahu 0...15kΩ)
- sw přepínatelný aktivní výstup 4-20mA nebo 0-20mA nebo 0-10V nebo inverzní převody
- pomocné napájení v širokém rozsahu 19 až 300VDC a 90 až 250VAC
- uživatelská konfigurace převodníku adaptérem AY-USB (AX-USB)
- provedení pro montáž na lištu DIN 35
- two-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- transfer 1:1 via transformer
- input voltage drop 2,8V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 4kV
- one measuring system - alternative connection in 1-phase
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- measurements high DC current or voltage both polarities
- max.input ± 600V or ± 6A
- 4-digit red LED display (height 20mm)
- universal power supply
- panel design IP65