Products
- one measuring system with phase shift
- alternative connection in 1-phase
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- Digital temperature transmitter with RS485 otput without galvanic isolation
- it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
- transmitter has auto-recognize for Pt100 or Pt1000 sensors
- we can set it for other input signals too
- communication by RS485 line with master device on baud rate 600..19200Bd
- measurements frequency, impulzes, turns
- standard analog signals
- 5-digit red LED display (height 14mm)
- up to 4 alarm contact
- output 0/4-20mA or 0-10V
- RS485 Modbus comunication
- 24V output supply
- galvanic separation
- universal power supply
- panel design IP65
- one-channel isolator
- conversion current signal 1:1
- current input and output powered via current loop
- response time 1ms
- accuracy 0,1%
- dielectric strength input / output 4kV
- two measuring systems with phase shift
- Aron connection
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- two-channel digital temperature transmitter with RS485 otput
- inputs are not galvanic isolated!
- it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
- transmitter has auto-recognize for Pt100 or Pt1000 sensors
- we can set it for other input signals too
- communication by RS485 line with master device on baud rate 600..19200Bd
- communication protocol ASCII or MODBUS-RTU
- measurements outputs from Pt100 resistance thermometers or J,K thermocouples
- standard analog signals current or voltage
- 5-digit red LED display (height 14mm)
- up to 4 alarm contact
- output 0/4-20mA or 0-10V
- RS485 Modbus comunication
- 24V output supply
- galvanic separation
- universal power supply
- panel design IP65
- two-channel isolator
- conversion current signal 1:1
- current input and output powered via current loop
- response time 1ms
- accuracy 0,1%
- dielectric strength input / output 4kV
- three measuring systems with phase shift
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- programmable converter with galvanic isolation 4000Veff input - output - power supply
- it is designed for transduction:
- temperature from any thermocouple with linearization and cold junction compensation
- resistance from resistance transmitter (potentiometer)
- temperature from thermistors, KTY or NTC sensors
- voltage 0..1V DC
- communication by RS485 line with master device on baud rate 600..19200Bd
- typically max. 56 transmitters on the line, distance max. 1200m
- communication protocol ASCII or MODBUS-RTU
- one-range converter
- isolation current signal 0/4..20mA 1:1
- accuracy 0,1%
- response time: 1ms
- power supply 18VDC for loop-powered transmitter on input
- dielectric strength input / output / supply power 4kV
- auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC
- digital processing of the input signal
- true RMS voltage measurement
- signal processing with crest factor up 4,5
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- two-channel programmable converter with galvanic isolation 4000Veff input - output - power supply
- inputs are galvanic isolated max. 1000V!
- is designed for transduction:
- temperature from any thermocouple with linearization and cold junction compensation
- resistance from resistance transmitter (potentiometer)
- temperature from thermistors, KTY or NTC sensors
- voltage 0..1V DC
- communication by RS485 line with master device on baud rate 600..19200Bd
- typically max. 56 transmitters on the line, distance max. 1200m
- communication protocol ASCII or MODBUS-RTU
- one-range converter
- bidirectional transmission of FSK signal HART communication
- isolation current signal 4..20mA 1:1
- accuracy 0,1%
- response time: 10ms
- power supply 18VDC for loop-powered transmitter on input
- dielectric strength input / output / supply power 4kV
- auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC
- digital processing of the input signal
- true RMS current measurement
- signal processing with crest factor up 4,5
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- digital processing of the input signal
- phase angle measurement between current and voltage
- phase angle measurement between current and voltage in the 3-phase 3-wire symmetrical balanced load grid
- phase angle measurement between two voltages in different grids
- output linear with phase angle φ in degrees
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- digital processing of the input signal
- calculated power factor cos φ
- output linear with power factor cos φ
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- digital processing of the input signal
- measurement frequency of AC grid
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- one measuring system
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered
- one measuring system - alternative connection with virtual neutral wire
- digital processing of the input signal
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output: 4000Vef
- loop-powered