Products
- converter with galvanic isolation 4000Veff input - output
- it is designed for transduction
- temperature from any thermocouple with linearization and cold junction compensation
- temperature from RTD, thermistors, KTY or NTC sensors
- resistance from resistance transmitter (potentiometer) 0..320Ω, 0..2500Ω
- easy programming by AX-USB adapter (AY-USB)
- ultra-slim design, DIN 35 rail-mounted, width 6mm
- two-state programmable temperature monitor
- compact design, IP 65 protection
- output relay with changeover contact
- Possibility of easy setting of switching value by potentiometer or programmed
- power voltage:
12V / 24V DC ± 25% without galvanic isolation
24V DC ± 10% with galvanic isolation 3kV
230V AC ± 10% (45 - 65 Hz) (transformer)
- isolation strength input / output / power 4kV
- the temperature adjusting element is inside the housing
- It is intended especially for monitoring of exceeding the set value, when the output relay switches (opens).
(Eg when the air temperature drops below the set limit of + 4 ° C the heating is switched on).
- 1 input
- 2 control outputs (heating, cooling)
- alarm output
- 4 event outputs
- 2 communication lines (PC, Master - Slave)
- 2 digital inputs
- 30 programs with 15 steps
- change in a program during its course
- start of the program with the key
- start of the program with the real-time clock
- datalogger, memmory of measured values
- one-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- transfer 1:1 via transformer
- input voltage drop 2,7V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 1,5kV
- measurements
- DC current or voltage both polarities
- outputs from Pt100 resistance thermometers or J,K thermocouples
- max.input ± 11V or ± 22mA
- 5-digit 3-colors LED display ( height 14mm)
- output open colector
- universal power supply
- panel design IP65
- digital processing of the input signal
- calculated power factor cos φ
- output linear with power factor cos φ
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- converter with galvanic isolation 4000Veff input - output
- it is designed for transduction:
- temperature from KTY temperature sensors and resistance transmitter 0-11kΩ
- easy programming by AX-USB adapter (AY-USB)
- ultra-slim design, DIN 35 rail-mounted, width 6mm
- 3 initial configurations of device:
- meter / alarm unit
- two-state controller
- PID controller
- 1 measuring input
- 2 outputs
- communication lines
- two-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- transfer 1:1 via transformer
- input voltage drop 2,7V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 1,5kV
- measurements
- AC current or voltage
- frequency
- 5-digit 3-colors LED display ( height 14mm)
- output open colector
- universal power supply
- panel design IP65
- digital processing of the input signal
- phase angle measurement between current and voltage
- phase angle measurement between current and voltage in the 3-phase 3-wire symmetrical balanced load grid
- phase angle measurement between two voltages in different grids
- output linear with phase angle φ in degrees
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- converter with galvanic isolation 4000Veff input - output
- it is designed for transduction:
- resistance transmitter (potentiometer) 0-11kΩ
- easy programming by AX-USB adapter (AY-USB)
- ultra-slim design, DIN 35 rail-mounted, width 6mm
- measurements small DC current or voltage both polarities
- max. input ± 11V or ± 22mA
- 4-digit red LED display (height 20mm)
- universal power supply
- panel design IP65
- one-channel passive isolator
- isolating converters 0/4..20mA with energy transfer
- bidirectional transmission of FSK signal HART communication
- transfer 1:1 via transformer
- input voltage drop 2,7V
- accuracy 0,1%
- response time 1ms
- dielectric strength input / output 1,5kV