Rawet s.r.o.
Manufacturing of regulation and measurement technology, transducers, temperature sensors.
Čapkova 22, 678 01 Blansko  Česká republika
+420 516 416 942 rawet@rawet.cz
Ověřená firma - ekatalog.cz ISO 9001:2008

Products

Total 254 items

N25H

Digital display - in design for panel
  • measurements high DC current or voltage both polarities
  • max.input ± 600V or ± 6A
  • 5-digit red LED display ( height 14mm)
  • universal power supply
  • panel design IP65

upon inquiry

N30H

Digital display - in design for panel
  • measurements high DC current or voltage both polarities
  • max.input ± 600V or ± 6A
  • 5-digit red LED display (height 14mm)
  • up to 4 alarm contact
  • output 0/4-20mA or 0-10V
  • RS485 Modbus comunication
  • 24V output supply
  • galvanic separation
  • universal power supply
  • panel design IP65

from €181.00 excl. VAT

GY200/HART

PASSIVE ISOLATING CONVERTER OF CURRENT SIGNAL WITH HART TRANSMISSION
  • one-channel passive isolator
  • bidirectional transmission of FSK signal HART communication
  • isolating converters 0/4..20mA with energy transfer
  • transfer 1:1 via transformer
  • input voltage drop 2,8V
  • accuracy 0,1%
  • response time 1ms
  • dielectric strength input / output 4kV

€88.40 excl. VAT

ACM-1Q4

REACTIVE POWER TRANSDUCER FOR 3-PHASE 4-WIRE BALANCED GRID
  • one measuring system with phase shift
  • alternative connection in 1-phase
  • digital processing of the input signal
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • universal power supply 19 – 300V DC & 90 – 250V AC

€159.80 excl. VAT
  • Digital temperature transmitter with RS485 otput without galvanic isolation
  • it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
  • transmitter has auto-recognize for Pt100 or Pt1000 sensors
  • we can set it for other input signals too
  • communication by RS485 line with master device on baud rate 600..19200Bd

€74.40 excl. VAT

N30O

Digital display - in design for panel
  • measurements frequency, impulzes, turns
  • standard analog signals
  • 5-digit red LED display (height 14mm)
  • up to 4 alarm contact
  • output 0/4-20mA or 0-10V
  • RS485 Modbus comunication
  • 24V output supply
  • galvanic separation
  • universal power supply
  • panel design IP65

from €181.00 excl. VAT

SIXISOL440/1

In stock
INPUT AND OUTPUT CIRCUIT POWERED ISOLATING CONVERTER
  • one-channel isolator
  • conversion current signal 1:1
  • current input and output powered via current loop
  • response time 1ms
  • accuracy 0,1%
  • dielectric strength input / output 4kV

€78.30 excl. VAT

ACM-2Q

REACTIVE POWER TRANSDUCER FOR 3-PHASE 3-WIRE UNBALANCED GRID
  • two measuring systems with phase shift
  • Aron connection
  • digital processing of the input signal
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • universal power supply 19 – 300V DC & 90 – 250V AC

€231.30 excl. VAT
  • two-channel digital temperature transmitter with RS485 otput
  • inputs are not galvanic isolated!
  • it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
  • transmitter has auto-recognize for Pt100 or Pt1000 sensors
  • we can set it for other input signals too
  • communication by RS485 line with master device on baud rate 600..19200Bd
  • communication protocol ASCII or MODBUS-RTU

€97.80 excl. VAT

N30U

Digital display - in design for panel
  • measurements outputs from Pt100 resistance thermometers or J,K thermocouples
  • standard analog signals current or voltage
  • 5-digit red LED display (height 14mm)
  • up to 4 alarm contact
  • output 0/4-20mA or 0-10V
  • RS485 Modbus comunication
  • 24V output supply
  • galvanic separation
  • universal power supply
  • panel design IP65

from €207.40 excl. VAT

SIXISOL440/2

In stock
TWO-CHANNEL INPUT AND OUTPUT CIRCUIT POWERED ISOLATING CONVERTER
  • two-channel isolator
  • conversion current signal 1:1
  • current input and output powered via current loop
  • response time 1ms
  • accuracy 0,1%
  • dielectric strength input / output 4kV

€112.90 excl. VAT

ACM-3Q

REACTIVE POWER TRANSDUCER FOR 3-PHASE 4-WIRE UNBALANCED GRID
  • three measuring systems with phase shift
  • digital processing of the input signal
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • universal power supply 19 – 300V DC & 90 – 250V AC

€270.10 excl. VAT
  • programmable converter with galvanic isolation 4000Veff input - output - power supply
  • it is designed for transduction:
       - temperature from any thermocouple with linearization and cold junction compensation
       - resistance from resistance transmitter (potentiometer)
       - temperature from thermistors, KTY or NTC sensors
       - voltage 0..1V DC
  • communication by RS485 line with master device on baud rate 600..19200Bd
  • typically max. 56 transmitters on the line, distance max. 1200m
  • communication protocol ASCII or MODBUS-RTU

€123.30 excl. VAT

ISOL400

In stock
SIGNAL 0/4..20mA REPEATER WITH AUXILIARY POWER SUPPLY
  • one-range converter
  • isolation current signal 0/4..20mA 1:1
  • accuracy 0,1%
  • response time: 1ms
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output / supply power 4kV
  • auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC

€90.50 excl. VAT

ACM-U/B

AC TRUE RMS VOLTAGE TRANSDUCER
  • digital processing of the input signal
  • true RMS voltage measurement 
  • signal processing with crest factor up 4,5
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output: 4000Vef
  • loop-powered

€123.10 excl. VAT
  • two-channel programmable converter with galvanic isolation 4000Veff input - output - power supply
  • inputs are galvanic isolated max. 1000V!
  • is designed for transduction:
       - temperature from any thermocouple with linearization and cold junction compensation
       - resistance from resistance transmitter (potentiometer)
       - temperature from thermistors, KTY or NTC sensors
       - voltage 0..1V DC
  • communication by RS485 line with master device on baud rate 600..19200Bd
  • typically max. 56 transmitters on the line, distance max. 1200m
  • communication protocol ASCII or MODBUS-RTU

€164.40 excl. VAT

ISOL400HART

SIGNAL 4..20mA REPEATER WITH HART TRANSMISSION AND AUXILIARY POWER SUPPLY
  • one-range converter
  • bidirectional transmission of FSK signal HART communication
  • isolation current signal 4..20mA 1:1
  • accuracy 0,1%
  • response time: 10ms
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output / supply power 4kV
  • auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC

€101.20 excl. VAT

ACM-I/B

AC TRUE RMS CURRENT TRANSDUCER
  • digital processing of the input signal
  • true RMS current measurement 
  • signal processing with crest factor up 4,5
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output: 4000Vef
  • loop-powered

€123.10 excl. VAT

ACM-P/B

PHASE ANGLE TRANSDUCER
  • digital processing of the input signal
  • phase angle measurement between current and voltage
  • phase angle measurement between current and voltage in the 3-phase 3-wire symmetrical balanced load grid
  • phase angle measurement between two voltages in different grids
  • output linear with phase angle φ in degrees
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output: 4000Vef
  • loop-powered

€170.70 excl. VAT

ACM-PF/B

POWER FACTOR TRANSDUCER
  • digital processing of the input signal
  • calculated power factor cos φ
  • output linear with power factor cos φ
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output: 4000Vef
  • loop-powered

€170.70 excl. VAT