ACM-F/B FREQUENCY TRANSDUCER digital processing of the input signal measurement frequency of AC grid conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €170.70 excl. VAT
ACM-1P/B ACTIVE POWER TRANSDUCER FOR 1-PHASE GRID one measuring system digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-1P3/B ACTIVE POWER TRANSDUCER FOR 3-PHASE 3-WIRE BALANCED GRID one measuring system - alternative connection with virtual neutral wire digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-1P4/B ACTIVE POWER TRANSDUCER FOR 3-PHASE 4-WIRE BALANCED GRID one measuring system - alternative connection in 1-phase digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-1Q/B REACTIVE POWER TRANSDUCER FOR 1-PHASE GRID one measuring system digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-1Q3/B REACTIVE POWER TRANSDUCER FOR 3-PHASE 3-WIRE BALANCED GRID one measuring system - alternative connection with virtual neutral wire digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-1Q4/B REACTIVE POWER TRANSDUCER FOR 3-PHASE 4-WIRE BALANCED GRID one measuring system - alternative connection in 1-phase digital processing of the input signal frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output: 4000Vef loop-powered Datasheet €159.80 excl. VAT
ACM-U/M AC TRUE RMS VOLTAGE TRANSDUCER WITH MODBUS OUTPUT digital processing of the input signal true RMS voltage measurement output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €123.10 excl. VAT
ACM-I/M AC TRUE RMS CURRENT TRANSDUCER WITH MODBUS OUTPUT digital processing of the input signal true RMS current measurement output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €123.10 excl. VAT
ACM-1P/M MULTIFUNCTIONAL TRANSDUCER FOR 1-PHASE GRID WITH MODBUS OUTPUT for 1-phase grid measurement RMS voltage, current, power factor, phase angle, active power and reactive power digital processing of the input signal output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €159.80 excl. VAT
ACM-1P3/M MULTIFUNCTIONAL TRANSDUCER FOR 3-PHASE 3-WIRE BALANCED GRID WITH MODBUS OUTPUT for 3-phase 3-wire balanced grid measurement RMS voltage, current, power factor, phase angle, active power and reactive power digital processing of the input signal output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €159.80 excl. VAT
ACM-1P4/M MULTIFUNCTIONAL TRANSDUCER FOR 3-PHASE 4-WIRE BALANCED GRID WITH MODBUS OUTPUT for 3-phase 4-wire balanced grid measurement RMS voltage, current, power factor, phase angle, active power and reactive power digital processing of the input signal output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €159.80 excl. VAT
ACM-2P/M MULTIFUNCTIONAL TRANSDUCER FOR 3-PHASE 3-WIRE UNBALANCED GRID WITH MODBUS OUTPUT for 3-phase 3-wire unbalanced grid measurement RMS voltage, current, active power and reactive power digital processing of the input signal output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €231.30 excl. VAT
ACM-3P/M MULTIFUNCTIONAL TRANSDUCER FOR 3-PHASE 4-WIRE BALANCED GRID WITH MODBUS OUTPUT for 3-phase 4-wire unbalanced grid measurement RMS voltage, current, power factor, phase angle, active power and reactive power digital processing of the input signal output RS485 (MODBUS RTU) signal processing with crest factor up 4,5 frequency range 40 … 1000Hz conversion accuracy 0,2% response time 300ms isolation input-output-power supply: 4000Vef universal power supply 19 – 300V DC & 90 – 250V AC Datasheet €270.10 excl. VAT