Rawet s.r.o.
Manufacturing of regulation and measurement technology, transducers, temperature sensors.
Čapkova 22, 678 01 Blansko  Česká republika
+420 516 416 942 rawet@rawet.cz
Ověřená firma - ekatalog.cz ISO 9001:2008

Products

Total 254 items

GXNB

ISOLATION CONVERTER WITH LIGHTNING IMPROVED RESISTANCE
  • isolation converter GXN with lightning improved resistance
  • one-range converter
  • converter provides additional protection lightning arresters and wire resistors in inputs and outputs
  • response time: 1ms
  • accuracy 0,1%
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output / supply power 4kV
  • auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC

€131.00 excl. VAT
  • two-state programmable temperature monitor
  • compact design, IP 65 protection
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • power voltage:
        12V / 24V DC ± 25% without galvanic isolation
        24V DC ± 10% with galvanic isolation 3kV
        230V AC ± 10% (45 - 65 Hz) (transformer)
  • isolation strength input / output / power 4kV
  • the temperature adjusting element is inside the housing
  • It is intended especially for monitoring of exceeding the set value, when the output relay switches (opens).
        (Eg when the air temperature drops below the set limit of + 4 ° C the heating is switched on).

€108.80 excl. VAT

GX440

INPUT AND OUTPUT CIRCUIT POWERED ISOLATING CONVERTER
  • convertor for standard unipolar signals
  • converter without auxiliary power supply
  • transfer via linear optocoupler
  • three-wire connection for voltages signals
  • two-wire connection for current signals
  • accuracy 0,1%
  • response time 1ms
  • dielectric strength input / output 4kV

€78.30 excl. VAT

N21

Digital display - in design for panel
  • measurements
    • measurements DC current or voltage both polarities
    • outputs from Pt100 resistance thermometers or J,K thermocouples
    • max. input ± 12V or ± 24mA
  • yellow-orange 5-digit OLED display
  • 2 x alarm contact
  • universal power supply
  • panel design IP65

€129.10 excl. VAT
  • two-state programmable temperature monitor
  • compact design, IP 65 protection
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • power voltage:
        12V / 24V DC ± 25% without galvanic isolation
        24V DC ± 10% with galvanic isolation 3kV
        230V AC ± 10% (45 - 65 Hz) (transformer)
  • isolation strength input / output / power 4kV
  • the temperature adjusting element is inside the housing
  • It is intended especially for monitoring of exceeding the set value, when the output relay switches (opens).
        (Eg when the air temperature drops below the set limit of + 4 ° C the heating is switched on).

from €105.80 excl. VAT
  • converter with galvanic isolation 4000Veff input - output
  • it is designed for transduction
       - temperature from any thermocouple with linearization and cold junction compensation
       - temperature from RTD, thermistors, KTY or NTC sensors
       - resistance from resistance transmitter (potentiometer) 0..320Ω, 0..2500Ω
  • easy programming by AX-USB adapter (AY-USB)
  • ultra-slim design, DIN 35 rail-mounted, width 6mm

€112.40 excl. VAT
  • two-state programmable temperature monitor
  • compact design, IP 65 protection
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • power voltage:
        12V / 24V DC ± 25% without galvanic isolation
        24V DC ± 10% with galvanic isolation 3kV
        230V AC ± 10% (45 - 65 Hz) (transformer)
  • isolation strength input / output / power 4kV
  • the temperature adjusting element is inside the housing
  • It is intended especially for monitoring of exceeding the set value, when the output relay switches (opens).
        (Eg when the air temperature drops below the set limit of + 4 ° C the heating is switched on).

from €112.40 excl. VAT

ISOL300/1

In stock
PASSIVE ISOLATING CONVERTER OF CURRENT SIGNAL
  • one-channel passive isolator
  • isolating converters 0/4..20mA with energy transfer
  • transfer 1:1 via transformer
  • input voltage drop 2,7V
  • accuracy 0,1%
  • response time 1ms
  • dielectric strength input / output 1,5kV

€48.20 excl. VAT

N20

Digital display - in design for panel
  • measurements
    • DC current or voltage both polarities
    • outputs from Pt100 resistance thermometers or J,K thermocouples
    • max.input ± 11V or ± 22mA
  • 5-digit 3-colors LED display ( height 14mm)
  • output open colector
  • universal power supply
  • panel design IP65

from €138.40 excl. VAT

ACM-PF

POWER FACTOR TRANSDUCER
  • digital processing of the input signal
  • calculated power factor cos φ
  • output linear with power factor cos φ
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • universal power supply 19 – 300V DC & 90 – 250V AC

€170.70 excl. VAT
  • converter with galvanic isolation 4000Veff input - output
  • it is designed for transduction:
       - temperature from KTY temperature sensors and resistance transmitter 0-11kΩ
  • easy programming by AX-USB adapter (AY-USB)
  • ultra-slim design, DIN 35 rail-mounted, width 6mm

€112.40 excl. VAT

Protokol analog ver. 1.1

Protokol pro nastavování pasivních převodníků ver. 1.1 používaný v RawetStudiu 2 pro převodníky od výrobního čísla 37xxxxx mimo převodníků PP200

N20Z

Digital display - in design for panel
  • measurements
    • AC current or voltage
    • frequency
  • 5-digit 3-colors LED display ( height 14mm)
  • output open colector
  • universal power supply
  • panel design IP65

upon inquiry

ACM-P

PHASE ANGLE TRANSDUCER
  • digital processing of the input signal
  • phase angle measurement between current and voltage
  • phase angle measurement between current and voltage in the 3-phase 3-wire symmetrical balanced load grid
  • phase angle measurement between two voltages in different grids
  • output linear with phase angle φ in degrees
  • conversion accuracy  0,2%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • universal power supply 19 – 300V DC & 90 – 250V AC 

€170.70 excl. VAT
  • converter with galvanic isolation 4000Veff input - output
  • it is designed for transduction:
       - resistance transmitter (potentiometer) 0-11kΩ
  • easy programming by AX-USB adapter (AY-USB)
  • ultra-slim design, DIN 35 rail-mounted, width 6mm

€112.40 excl. VAT