- Homepage
- Products
-
Transmitters for temperature , resistance or potentiometric sensors
Transmitters for temperature , resistance or potentiometric sensors
- inbuilt transmitter PP200 powered from output current loop
- it is programmable for sensors Pt100, Pt1000, Ni 100, Ni1000
- current output 4-20mA
- programmable range, min. span 10°C
- accuracy ±(0,07%+0,1°C)
- easy programming range by AX-USB adapter (AY-USB) without power supply
- inbuilt transmitter PP300 with power supply 12-30V DC
- it is designed for:
- resistance from resistance transmitter (potentiometer) 0..100Ω, 0..1kΩ and 0..10kΩ
- voltage 0-10V DC, thermistors by request
- voltage output 0-10V
- programmable range, min. span 10°C
- accuracy ±(0,07%+0,1°C)
- easy programming range by AX-USB adapter (AY-USB) without power supply
- inbuilt transmitter PX300 powered from output current loop
- galvanic isolation input - output - power supply: 1200Veff
- transmitter with 4-20mA output is designed for:
- temperature from any thermocouple with linearization and cold junction compensation
- resistance from resistance transmitter (potentiometer)
- thermistors, KTY, NTC e.t.c.
- easy programming range by AX-USB adapter (AY-USB) without power supply
- inbuilt transmitter PPL100
- it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
- transmitter has auto-recognize for Pt100 or Pt1000 sensors
- we can set it for other input signals too
- communication by RS485 line with master device on baud rate 600..19200Bd
- communication protocol ASCII or MODBUS-RTU
- převodník je určen do hlavice teploměru rozměr DIN „B“
- uživatelská konfigurace převodníku
- převodník s výstupem 0-10V je určen k převodu signálu z Pt100, Pt1000, Ni100 a Ni1000,
- PP200 is mounted in a connection head DIN "B" dimension or any box
- converter without galvanic isolation, converts temperature from RTD to 4..20mA
- easy programming range by AX-USB adapter (AY-USB) without power supply
- the transmitter can be programmed for the types of sensors: Pt100, Pt1000, Ni 100, Ni 1000, KTY81..
- converter without galvanic isolation
- it converts temperature from RTD or resistance from resistance transmitter to 4..20mA
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
- transmitter is mounted in a connection head DIN "B" dimension or any box
- easy programming by AX-USB adapter (AY-USB) without power supply
- transmitter with 0..10V ouput is designed for:
- any RTD sensor, resistance transmitter or potentiometer 0..100Ω, 0..1kΩ and 0..10 kΩ
- voltage 0..10V, thermistors..
- two-channel converter PP210 without galvanic isolation
- it converts temperature from RTD or resistance from resistance transmitter to 4..20mA
- easy programming by AX-USB adapter (AY-USB) without power supply
- each channel can be set independently
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
- converter without galvanic isolation
- it converts temperature from any thermocouple to 4..20mA
- cold junction compensation
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
- transmitter is mounted in a connection head DIN "B" dimension or any box
- galvanic isolation input - output - power supply: 1200Vef
- easy programming by AX-USB adapter (AY-USB) without power supply
- Transmitter with 4..20mA ouput is designed for:
- any thermocouple with linearization and cold junction compensation
- any RTD sensor or resistance transmitter
- thermistors, KTY, NTC..
- two-channel converter PP210_Tc without galvanic isolation
- it converts temperature from any thermocouple to 4..20mA
- cold junction compensation
- easy programming by AX-USB adapter (AY-USB) without power supply
- each channel can be set independently
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
- transmitter is mounted in a connection head DIN "MAA" dimension or any box
- easy programming by AX-USB adapter (AY-USB) without power supply
- it converts temperature from RTD thermometer to 4..20mA
- transmitter can be set for sensors Pt100/Ni100 or Pt1000/Ni1000
- converter without galvanic isolation
- transmitter with 4-20mA otput is designed for transduction:
- voltage from any thermocouple with linearization and cold junction compensation
- temperature from RTD or resistance from resistance transmitter
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply by output loop 11…30V DC, any polarity
- slim design, DIN 35 rail-mounted, width 12,5mm
- transmitter is mounted in a connection head DIN "B" dimension or any box
- it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
- transmitter has auto-recognize for Pt100 or Pt1000 sensors
- we can set it for other input signals too
- communication by RS485 line with master device on baud rate 600..19200Bd
- converter without galvanic isolation
- transmitter with 0-10V otput is designed for transduction:
- temperature from RTD or resistance from resistance transmitter
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply 12…30V DC
- slim design, DIN 35 rail-mounted, width 12,5mm
- converter with galvanic isolation 4000Veff
- it is designed for transduction:
- temperature from any thermocouple with linearization and cold junction compensation
- temperature from RTD or resistance from resistance transmitter
- voltage 0-1V DC
- easy programming by AX-USB adapter (AY-USB)
- power supply 8…30V DC
- DIN 35 rail-mounted design
- converter with galvanic isolation 3700Veff
- it is designed for transduction:
- temperature from any thermocouple with linearization and cold junction compensation
- temperature from RTD or resistance from resistance transmitter
- voltage 0-1V DC
- easy programming by AX-USB adapter (AY-USB)
- power supply 8…30V DC
- slim design, DIN 35 rail-mounted, width 12,5mm
- converter with galvanic isolation 4000Veff input - output
- it is designed for transduction
- temperature from any thermocouple with linearization and cold junction compensation
- temperature from RTD, thermistors, KTY or NTC sensors
- resistance from resistance transmitter (potentiometer) 0..320Ω, 0..2500Ω
- easy programming by AX-USB adapter (AY-USB)
- ultra-slim design, DIN 35 rail-mounted, width 6mm
- converter with galvanic isolation 4000Veff input - output
- it is designed for transduction:
- temperature from KTY temperature sensors and resistance transmitter 0-11kΩ
- easy programming by AX-USB adapter (AY-USB)
- ultra-slim design, DIN 35 rail-mounted, width 6mm