- thermowells
- adjustable threads
- welded-on pieces
- holder for air conditioning
Temperature sensors
(You can see description of sensors after click on Types, detailed tables are below)
|
Type |
Description |
TCR [ppm/°C] |
Tolerance [°C] |
Max. temp. [°C] |
|
|
A |
B |
||||
|
Platinum sensor 100Ω / 0°C |
3851 |
0,15+0,002t |
0,30+0,005t |
-70..+600 |
|
|
Platinum sensor 1000Ω / 0°C |
3851 |
0,15+0,002t |
0,30+0,005t |
-70..600 |
|
|
Nickel sensor 100Ω / 0°C |
6180 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
|
Nickel sensor 1000Ω / 0°C |
6180 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
|
Nickel sensor 1000Ω / 0°C |
5000 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
|
Termocouple Fe-Ko |
c. 5,37mV/100°C |
-200..+750 |
|||
|
Termocouple Ch-A |
c. 4,80mV/100°C |
-200..+1200 |
|||
|
Termistor NTC (variety of) |
nonlinear |
±2..±5% |
-40..+125 |
||
|
Thermistor PTC with T sens |
nonlinear |
±5°C |
max. +180 |
||
|
Linear semicond. sensor |
c. 0,79%/K |
±1 .. ±5°C |
-55..+150 (+300) |
||
|
Sensor SMARTEC |
- |
±0,7°C |
-45..+130 |
||
|
Sensor DALLAS |
- |
±0,5°C |
-10..+85 |
||
|
Ton=+45..+145°C (by 5°C) |
- |
Ts ±5°C |
145 |
||
|
Toff=+45..+145°C (by 5°C) |
- |
Ts ±5°C |
145 |
||
Attachment for downloads:
(in TXT format for easy linearization in PC)
PT31K (DIN)
- connector DIN43650
- diameter 5 to 8mm (or others), fitting length „Y“ according to order
- screw fitting: M10x1, M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- basic design: 8x100mm Pt100/B G1/2 2w max. 100°C
- temperature range: -30…+100° (T=c. 7sec)
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
- metal parts are made from stainless steel 17248
- enclosure IP code: IP65
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
PT31M12
- connector M12x1 EC-FS4-L/16
- diameter 5 to 8mm (or others), fitting length „Y“ according to order
- screw fitting: M10x1, M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- basic design: 8x100mm Pt100/B G1/2 2w max. 90°C
- temperature range: -30…+90° (T=c. 7sec)
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
- metal parts are made from stainless steel 17248
- enclosure IP code: IP67 (threaded connector)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
PTP10K
- for outdoor use, IP65
- it can be use transmitters
- PP200 with output 4…20mA
- PP300 with output 0…10V
- PPL100 with output ASCII or MODBUS - power supply by output loop 8…28V ss, ripple max. 0,5V
- any measuring range, min. span 10°C
- accuracy ±0,3% from span (max. ±0,25°C)
- another parameters are shown in the datasheet of used transmitter
- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- cable thermometer Ø 4 .. 8mm for bearing, uninsulated stem
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -60…+350°C (T=c. 10sec)
- dielectric strength: 1500V, insulation resistance min. 20MΩ
- Immersion length Y = depth of hole+ 10mm! Spring compressionis max. 20mm.
PM55PR
new- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- basic design Ø6mm, -25…+200°C (T=c. 10sec) or –25…+400°C (T=c. 25sec)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4..
- stem from stainless steel Ø 3, 4, 5 or 6mm
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
PMP55PR
new- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- basic design Ø6mm, -25…+200°C (T=c. 10sec) or –25…+400°C (T=c. 25sec)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4..
- stem from stainless steel Ø 3, 4, 5 or 6mm
- inbuilt programmable transmitter PMA300 with 4…20mA output
- power supply by output loop 8…30V DC, ripple max. 0,5V
- any measuring range <-50…+80>°C, min. span 50°C
- accuracy ±0,5% from span (max. ±0,25°C)
- another parameters are shown in the datasheet of used transmitter PMA300
- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- cable thermometer Ø 6mm for bearing, with insulated stem
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -60…+200°C (T=c. 10sec)
- dielectric strength: 1500V, insulation resistance min. 20MΩ
- Immersion length Y = depth of hole+ 10mm! Spring compressionis max. 20mm.
Kabel RKC 4/7 M12 1m
- sensor is built-in to plastic box, wall mounting design
- sensor 1x Pt100A, B, Pt1000, Ni1000 or others
- accuracy according to used sensor
NIP20
- sensor is built-in to plastic box, wall mounting design
- connecting by three wires (GND, OUT, +Ucc)
- power supply 12…34V DC
- voltage ripple max. 0,5V
- measuring range 0…+50°C (or others)
- output 0…5V
- accuracy +/- 0,3°C
PT31K/H
- connector DIN43650
- diameter 5 to 8mm (or others), fitting length „Y“ according to order
- purpose: to sink intro the lock fitting bracket or air conditioning
- basic design: 8x100mm Pt100/B G1/2 2w max. 100°C
- temperature range: -30…+100° (T=c. 7sec)
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
- metal parts are made from stainless steel 17248
- enclosure IP code: IP65
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
PT31M12/H
- connector M12x1 EC-FS4-L/16
- diameter 5 to 8mm (or others), fitting length „Y“ according to order
- purpose: to sink intro the lock fitting bracket or air conditioning
- basic design: 8x100mm Pt100/B G1/2 2w max. 100°C
- temperature range: -30…+100° (T=c. 7sec)
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
- metal parts are made from stainless steel 17248
- enclosure IP code: IP65
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
PTP31M12
new- connector M12x1 EC-FS4-L/16
- diameter 6 or 8mm (or others), fitting length „Y“ according to order
- screw fitting: M10x1, M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- basic design: 8x100mm Pt100/B G1/2 2w max. 100°C
- temperature range: -30…+100° (T=c. 7sec), extended range -30°...+400°C
- used programmable transmitter PMA300 with output 4…20mA
- power supply by output loop 8…28V DC, ripple max. 0,5V
- any measuring range <-50…+400>°C, min. span 50°C
- accuracy ±0,5% from span (max. ±0,25°C)
- another parameters are shown in the datasheet of used transmitter PMA300
- metal parts are made from stainless steel 17248
- enclosure IP code: IP67 (threaded connector)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
PT50V
- základní provedení Ø8mm, -25…+200°C (T=cca 10sec) nebo –25…+400°C (T=cca 25sec)
- výběr ze šroubení: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4..
- stonek je možné vyrobit Ø 8 nebo 10mm
- lze osadit Pt100/A, B, dvou až čtyřvodičovém zapojení, dvojité čidlo, Pt1000, Ni1000, KTY, PTC, termočlánky…
- přesnost závisá na typu použitého čidla
PT50HV
- základní provedení Ø8mm, -25…+200°C (T=cca 10sec) nebo –25…+400°C (T=cca 25sec)
- stonek Ø 8 nebo 10mm
- vložka se plastovou nebo keramickou svorkovnicí
- lze osadit Pt100/A, B, dvou až čtyřvodičovém zapojení, dvojité čidlo, Pt1000, Ni1000, KTY, PTC, termočlánky…
- přesnost závisá na typu použitého čidla
PT50JV
- základní provedení: stonek Ø8mm, jímka Ø10mm
- rozsah měření -25…+200°C (T=cca 30sec) nebo –25…+400°C (T=cca 50sec)
- výběr ze šroubení: G1/2; M20x1,5; M27x2, G3/4....
- lze osadit Pt100/A, B, dvou až čtyřvodičovém zapojení, dvojité čidlo, Pt1000, Ni1000, KTY, PTC, termočlánky…
- přesnost závisá na typu použitého čidla