Temperature sensor into thermowells or onto pipes, cable with insulation from fiberglass is wired in thermometers body. Stem is made from stainless steel 17248, optional dimensions and design.
basic design: 6x50mm Pt100/B with cable 4w 1m
it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
temperature range -10…+350°C with cable BIMV-CNTEVS (T=c. 7sec)
dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
Temperature sensor for screwing into thermowells or welded-on pieces, cable with insulation from fiberglass is wired in thermometers body. Stem is made from stainless steel 17248, optional dimensions and design.
screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, thermocouples…
temperature range -10…+350°C with cable BIMV-CNTEVS (T=c. 7sec)
dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
Multi-purpose temperature and resistance transmitter with galvanic isolation
transmitter is mounted in a connection head DIN "B" dimension or any box
galvanic isolation input - output - power supply: 1200Vef
easy programming by AX-USB adapter (AY-USB) without power supply
Transmitter with 4..20mA ouput is designed for:
- any thermocouple with linearization and cold junction compensation
- any RTD sensor or resistance transmitter
- thermistors, KTY, NTC..
Temperature sensor into thermowells or onto pipes, cable is wired in thermometers body, plastic bushing increases water-proof and bend resistance. Stem is made from stainless steel 17248, optional dimensions and design.
basic design: 6x50mm Pt100/B with cable 4w 1m
it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
temperature range -30…+80°C with cable PVC IP68 (T=c. 7sec)
dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
Temperature sensor for screwing into thermowells or welded-on pieces, cable is wired in thermometers body, plastic bushing increases water-proof and bend resistance. Stem is made from stainless steel 17248, optional dimensions and design.
screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
temperature range -30…+80°C with PVC cable IP68 (T=c. 7sec)
dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)