with cable
Total 20 items
- sealed design, stem from insulation material
- -40…+150°C (class „F“)
- it can be use Pt100/A, B, from two to four wire connection, Pt1000, Ni1000, PTC, thermocouples…
- leads are made from stranded wire with PTFE insulation, 2,5m length
- sensor is sealed into laminated plastic material and covered by teflon shrinkable tube
- -40…+180°C (class „H“)
- it can be use Pt100/A, B, from two to four wire connection, Pt1000, Ni1000, PTC, thermocouples…
- leads are made from stranded wire with PTFE insulation, 2,5m length
- basic design 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- basic design 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, PTC, thermocouples…
- temperature range -40…+200°C with cable MCBE-AFEP
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- basic design 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, thermocouples…
- temperature range -10…+350°C with cable BIMV-CNTEVS
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- for outdoor use, IP65
- it can be use transmitters
- PP200 with output 4…20mA
- PP300 with output 0…10V
- PPL100 with output ASCII or MODBUS
- power supply by output loop 8…28V ss, ripple max. 0,5V
- any measuring range, min. span 10°C
- accuracy ±0,3% from span (max. ±0,25°C)
- another parameters are shown in the datasheet of used transmitter
- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- cable thermometer Ø 4 .. 8mm for bearing, uninsulated stem
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -60…+350°C (T=c. 10sec)
- dielectric strength: 1500V, insulation resistance min. 20MΩ
- Immersion length Y = depth of hole+ 10mm! Spring compressionis max. 20mm.
- spring-loaded protection tube that ensures metallic contact between bearing and sensor
- cable thermometer Ø 6mm for bearing, with insulated stem
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -60…+200°C (T=c. 10sec)
- dielectric strength: 1500V, insulation resistance min. 20MΩ
- Immersion length Y = depth of hole+ 10mm! Spring compressionis max. 20mm.
- adjustable immersion length, adjustable thread M12x1,75 or G1/2 or others by request - inclusive hermetic design.
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+150°C (T=c. 15sec)
- dielectric strength: 1500V, insulation resistance min. 20MΩ (circuit to metal parts)
- sensor Pt100 is covered by teflon shrinkable tube only
- it can be use Pt100/A, B, from two to four wire connection, Pt1000, Ni1000, PTC, thermocouples…
- max. +200°C
- leads are made from stranded wire with PTFE insulation, 2,5m length
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+200°C with cable MCBE-AFEP (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+200°C with cable MCBE-AFEP (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -10…+350°C with cable BIMV-CNTEVS (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, thermocouples…
- temperature range -10…+350°C with cable BIMV-CNTEVS (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with cable PVC IP68 (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable IP68 (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- stem from stainless steel diameter 5, 4 or 3mm, min. length 15mm
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+200°C
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- stem from stainless steel diameter 4 or 3mm, min. length 15mm
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, thermocouples…
- temperature range -10…+400°C
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)