Products
- It provide a voltage corresponding pH value in range 0..14
- optional output 4..20mA, 0..10V or MODBUS
- dielectric strength input / output 1,5 kV
- DIN 35 rail-mounted design
- 2-wire temperature compensation Pt, Ni
- calibration in 2 points 10/4pH and 7pH
- active output 4-20mA or 0-20mA or 0-10V resp. inverse transfers
- converts signal:
- from any thermocouple with linearization and internal cold junction compensation
- from RTD, resistive transmitter or potentiometer
- NTC, KTY
- user configuration of AY-USB adapter
- Rated impulse voltage Uni: 6kV
- auxiliary power supply in a wide range of 16-300V DC and 90-250V AC
- accuracy <0.1%
- version for mounting into switchboard on DIN 35 rail
- measurements in 1-phase grid
- RMS voltage or current
- active or reactive power
- phase angle
- power factor
- RMS current with direction ( supply or consumption)
- output of up to 2 relays, analog output, RS485
- 4-digit display (digit height 20mm)
- LED display color red or green
- power supply 19..300VDC & 90..250VAC
- panel design
- to display the measured value
- monitoring of exceeding the set value
- for outdoor use, IP65, -50…+80°C
- it can be use transmitters
- PP200 with output 4…20mA
- PP300 with output 0…10V
- PPL100 with output ASCII or MODBUS
- power supply by output loop 8…28V ss, ripple max. 0,5V
- any measuring range <-50…+80>°C, min. span 50°C
- accuracy ±0,5% from span (max. ±0,25°C)
- another parameters are shown in the datasheet of used transmitter
- mounting on pipe with diameter 40-60mm by metallic cable tie or by stainless steel zip ties for any diameter
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+200°C with cable MCBE-AFEP (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -40…+200°C with cable MCBE-AFEP (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
- digital processing of the input signal
- transducer for measurement DC current or voltage
- allows unipolar and bipolar input and output signal
- directly current measurements up to ±10A, voltage up to ±1000V DC
- ability to measure absolute values and inverted signal
- conversion accuracy <0,1%
- response time 50ms
- dielectric strength input / output / supply power 4kV
- universal power supply 19 – 300V DC & 90 – 250V AC
- 3 initial configurations of device:
- meter / alarm unit
- two-state controller
- PID controller
- 1 measuring input
- 2 outputs
- communication lines
- 24 calibrated ranges
- isolation unipolar and bipolar signals
- setting ranges by slid switches DIP on the board
- digital processing and transfer A/D and D/A
- response time: < 50ms
- accuracy 0,1%
- power supply 18VDC for loop-powered transmitter on input
- dielectric strength input / output / supply power 4kV
- auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC
- programming adapter for Rawet R24 display and Lumel N20, N24, N25 ... and others
- programming software for RawetStudio2 and eCon
- analog measurement
- true RMS value of current or voltage
- signal processing with crest factor up 10
- frequency range 40 … 1000Hz
- conversion accuracy 0,5%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
- converter without galvanic isolation
- it converts temperature from any thermocouple to 4..20mA
- cold junction compensation
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
- 4-20mA loop-powered
- transducer for measurement DC current or voltage
- directly current measurements up to ±10A DC, voltage up to ±1500V DC
- analog measurement of the input signal
- accuracy <0,1%
- response time 1ms
- rated impuls voltage Uni: 8kV
- dielectric strenght Ua input / output: 5kVrms
- clearances and creepage distances min. 8mm
- designed for DIN 35 rail mounting
- measures the product of two input signals 0/4-20mA
- display unit in Watts
- output of up to 4 relays, analog output, RS485
- 4-digit display (digit height 20mm)
- LED display color red or green
- power supply 19..300VDC & 90..250VAC
- panel design
- to display the measured value
- monitoring of exceeding the set value
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- for outdoor use, IP65, -50…+100°C
- It provide a voltage corresponding pH value in range 0..14
- optional output 4..20mA, 0..10V or MODBUS
- dielectric strength input / output 1,5 kV
- wall-mounted design, plastic box IP65
- 2-wire temperature compensation Pt, Ni
- calibration in 2 points 10/4pH and 7pH