PX24
ISOLATED TRANSDUCER OUTPUT CURRENT LOOP-POWERED
- analog measurement of the input signal
- transducer for measurement DC current or voltage
- directly current measurements up to ±10A, voltage up to ±1000V DC
- accuracy <0,1%
- response time 1ms
- dielectric strength input / output 4kV
- loop powered
€108.40 excl. VAT
ISOL100
In stock
FAST ISOLATING CONVERTER FOR UNIPOLAR AND BIPOLAR SIGNALS WITH SWITCHABLE CALIBRATED RANGES
- fast respons time (0,1ms)
- 8 calibrated ranges
- isolation unipolar and bipolar signals
- setting range by slid switch DIP on the board
- bandwidth : 0..5kHz for -0,5dB
- fast analog channel digitally driven
- accuracy 0,1%
- power supply 18VDC for loop-powered transmitter on input
- dielectric strength input / output / supply power 4kV
- auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC
€107.30 excl. VAT
- limit guard with user-defined level
- up to two separate switching / disconnecting channels
- input signal U / I or RTD or Tc
- LED display 4digity height
- relay output: no relay or 1 to 2 changeover relays
- analog output: 0-20mA or 4-20mA or 0-10V or no output
- auxiliary power supply in a wide range of 19 to 300VDC and 90 to 250VAC
- power consumption: max. 2VA
- monitoring of set limit of switching and opening of two switches according to input signal value
- display of measured value in range -999… 9999 digit
- isolation strength input / power 4kV
from
€157.40 excl. VAT
- measurements
- RTD, Tc, R, U, I
- unified signals 0-20mA, 4-20mA, 0-10V ....etc.
- voltage or current DC
- output of up to 4 relays, analog output, RS485
- 4-digit display (digit height 20mm)
- LED display color red or green
- power supply 19..300VDC & 90..250VAC
- panel design
- to display the measured value
- monitoring of exceeding the set value
from
€98.40 excl. VAT
AY-USB
Programming Adapter for Rawet Converters.
- adapter for Programming Transducers with Galvanic Separation
- direct replacement for adapters AX-USB a PK-USB
- for transduceres:
PP200, PP300, PMA300, PX300, PP210/212, PP210/S
PP200-BOX, PP300-BOX, PX300-BOX
PX310, PX310S,ISOL600, PXN30
SIXISOL310, SIXISOL600
TS30, TS30K, TS30DIN, DPR40 - programming software Rawet Studio
€55.60 excl. VAT
ACM-I
AC TRUE RMS CURRENT TRANSDUCER
- digital processing of the input signal
- true RMS current measurement
- signal processing with crest factor up 4,5
- frequency range 40 … 1000Hz
- conversion accuracy 0,2%
- response time 300ms
- isolation input-output-power supply: 4000Vef
- universal power supply 19 – 300V DC & 90 – 250V AC
€126.50 excl. VAT
- PP200 is mounted in a connection head DIN "B" dimension or any box
- converter without galvanic isolation, converts temperature from RTD to 4..20mA
- easy programming range by AX-USB adapter (AY-USB) without power supply
- the transmitter can be programmed for the types of sensors: Pt100, Pt1000, Ni 100, Ni 1000, KTY81..
€60.50 excl. VAT
- converter without galvanic isolation
- it converts temperature from RTD or resistance from resistance transmitter to 4..20mA
- easy programming by AX-USB adapter (AY-USB) without power supply
- power supply by output loop 8…30V DC, any polarity
- DIN 35 rail-mounted design
€74.90 excl. VAT
PT04
Sensor with cable is designed for surface temperature measurement on pipes. for outdoor use (IP65), -25…+120°C, any sensor.
- mounting on pipe with diameter 40-60mm by metallic cable tie or by stainless steel zip ties for any diameter
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
from
€17.10 excl. VAT
- 4..20mA loop powered
- Rated impulse voltage Uni: 6kV
- converts signal:
- from any thermocouple with linearization and internal cold junction compensation
- from RTD, resistive transmitter or potentiometer
- NTC, KTY
- user configuration of AY-USB adapter
- accuracy <0.1%
- version for mounting into switchboard on DIN 35 rail
€130.40 excl. VAT
PT10
In stock
Temperature sensors for outdoor use, plastic connection head with stainless stem, proof design (IP65).
- for outdoor use, IP65, -50…+100°C
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- accuracy according to used sensor
from
€50.00 excl. VAT
Měření pH - teorie
Pojednání o měření pH pro "nechemiky"
PT30 max. 80°C
Temperature sensor into thermowells or onto pipes, PVC cable is wired in thermometers body. Stem is made from stainless steel 17248, optional dimensions and design.
- basic design: 6x50mm Pt100/B with cable 4w 1m
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
from
€23.90 excl. VAT
PT31 80°C
Temperature sensor for screwing into thermowells or welded-on pieces, PVC cable is wired in thermometers body. Stem is made from stainless steel 17248, optional dimensions and design.
- screw fitting: M12x1,5 M12x1,75; G1/4, G1/2; M20x1,5; M27x2, G3/4 or others by request
- it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
- temperature range -30…+80°C with PVC cable (T=c. 7sec)
- dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)
from
€29.20 excl. VAT
PXN
ISOLATED TRANSDUCER WITH POWER SUPPLY AND ACTIVE OUTPUT
- digital processing of the input signal
- transducer for measurement DC current or voltage
- allows unipolar and bipolar input and output signal
- directly current measurements up to ±10A, voltage up to ±1000V DC
- ability to measure absolute values and inverted signal
- conversion accuracy <0,1%
- response time 1ms, per order up to 300ms
- dielectric strength input / output / supply power 4kV
- universal power supply 19 – 300V DC & 90 – 250V AC
€123.60 excl. VAT
Ht60B
Easy-to-use PID controller
GXN200
In stock
ISOLATING CONVERTER FOR UNIPOLAR AND BIPOLAR SIGNALS WITH SWITCHABLE CALIBRATED RANGES
- 24 calibrated ranges
- isolation unipolar and bipolar signals
- setting ranges by slid switches DIP on the board
- digital processing and transfer A/D and D/A
- response time: 1ms, adjustable to 100ms by switch
- accuracy 0,1%
- power supply 18VDC for loop-powered transmitter on input
- dielectric strength input / output / supply power 4kV
- auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC
€123.60 excl. VAT
AY-USB/485
Programming Adapter for Rawet Converters.
- adapter for Programming Transducers with Galvanic Separation
- direct replacement for adapters AX-USB a PK-USB
- for transduceres:
PPL100, PPL110, PPL112
PXL310, PXl312
PPL100-BOX - programming software Rawet Studio
€55.60 excl. VAT